dc.description.abstract | Al realizar varios diseños de sistemas de alcantarillado, se observó que en muchos casos los diámetros mínimos exigidos resultan sobredimensionados, para el caudal que estos trasportan, con lo que algunos parámetros hidráulicos no cumplían con la normatividad vigente. Lo anterior nos motiva a la posibilidad de disminuir los diámetros mínimos exigidos para transportar ese caudal sin que los parámetros hidráulicos superen los límites máximos y mínimos establecidos. Inicialmente se investigó la evolución de la normatividad, en cuanto a diámetros y parámetros hidráulicos se refiere, para entrar en contexto de la posibilidad de disminución de diámetros, y para completar el análisis, fue importante hacer mención de la hidráulica de la tubería, y enunciar los parámetros técnicos y legales que inciden en el diseño de los sistemas de acueducto, y que están incluidos en la normatividad vigente. Teniendo claro lo anterior, se escogieron unas poblaciones de nivel de complejidad bajo y medio, para hacer las modelaciones tanto con el diámetro mínimo exigido, como con el diámetro optimizado, y una vez hecho esto, se analizaron y compararon los resultados obtenidos tanto técnicos, hidráulicos y económicos. Finalmente con los resultados obtenidos, se plantearon las conclusiones y recomendaciones sobre la posibilidad de reducir la sección de diámetro mínimo exigido en la normatividad vigente. | spa |
dc.description.abstract | With several designs sewage systems, it was observed that in many cases the required minimum diameters are dimensioned for these transporting flow, which some hydraulic parameters did not meet current regulations. This motivates us to the possibility of lowering the minimum diameters required for transporting the flow without hydraulic parameters exceed the maximum and minimum limits. Initially the evolution of the regulations was investigated in terms of diameters and hydraulic parameters are concerned, to enter context of the possibility of decreasing diameters, and to complete the analysis, it was important to mention hydraulic pipe, and enunciate technical and legal parameters that affect the design of water systems, and are included in current regulations. Taking clear above, a population level low and medium complexity were chosen for the modeling both the minimum diameter required, as with optimized diameter, and once done, were analyzed and compared the results both technical, hydraulic and economic. Finally with the results, conclusions and recommendations on the possibility of reducing the minimum diameter section required by current regulations were raised. | eng |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.publisher | Escuela Colombiana de Ingeniería Julio Garavito | spa |
dc.rights | Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | spa |
dc.subject | Nivel de complejidad | spa |
dc.subject | Diámetro mínimo | spa |
dc.subject | Presión máxima | spa |
dc.subject | Presión mínima | spa |
dc.subject | Velocidad máxima | spa |
dc.subject | Velocidad mínima | spa |
dc.title | Evaluación de diámetros mínimos para conducciones y redes de distribución para poblaciones de nivel de complejidad bajo y medio – RAS 2000 | spa |
dc.type | Trabajo de grado - Maestría | spa |
dc.type.version | info:eu-repo/semantics/publishedVersion | spa |
oaire.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.description.degreelevel | Maestría | spa |
dc.description.degreename | Magíster en Ingeniería Civil con Énfasis en Recursos Hidráulicos y Medio Ambiente | spa |
dc.publisher.program | Maestría en Ingeniería Civil con Énfasis en Recursos Hidráulicos y Medio Ambiente | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.creativecommons | Atribución-NoComercial 4.0 Internacional (CC BY-NC 4.0) | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | spa |
dc.type.content | Text | spa |
dc.type.driver | info:eu-repo/semantics/masterThesis | spa |
dc.type.redcol | http://purl.org/redcol/resource_type/TM | spa |
dc.subject.keywords | Level of complexity | spa |
dc.subject.keywords | Minimum diameter | spa |
dc.subject.keywords | Maximum pressure | spa |
dc.subject.keywords | Minimum pressure | spa |
dc.subject.keywords | Maximum speed | spa |
dc.subject.keywords | Minimum speed | spa |