Mostrar el registro sencillo del ítem

dc.contributor.advisorChaparro Preciado, Javier Alberto (dir)spa
dc.contributor.authorBonilla Hernández, Cesar Alexander.spa
dc.date.accessioned2015-02-09T16:04:51Zspa
dc.date.accessioned2021-10-01T15:57:12Z
dc.date.available2015-02-09T16:04:51Zspa
dc.date.available2021-10-01T15:57:12Z
dc.date.issued2015spa
dc.identifier.urihttp://catalogo.escuelaing.edu.co/cgi-bin/koha/opac-detail.pl?biblionumber=17447spa
dc.identifier.urihttps://repositorio.escuelaing.edu.co/handle/001/167
dc.description.abstractLos médicos actualmente se enfrentan a uno de los procesos más complicados dentro de esta rama de la ciencia, debido a que la recuperación de los pacientes muchas veces es medida por la capacidad respiratoria propia de cada individuo, convirtiéndose en un factor de alto riesgo para las personas que se encuentran en las unidades de cuidados intensivos, razón por la cual este trabajo propone un prototipo de Monitor de Flujo Respiratorio, que permita a los médicos medir la capacidad respiratoria de cada uno de los pacientes, para poder realizar el proceso de extubacion con el menor riesgo posible para la vida de los mismos. Con el avance en la investigación se propone el diseño de un prototipo de monitor de flujo respiratorio para pruebas de índices de extubacion, que genere criterios para la evaluación de índices, durante el proceso, por el método de prueba de tubo en T, ayudando al médico en la toma de decisiones. Para la elaboración de este prototipo de Monitor de Flujo Respiratorio para pruebas de respiración instantánea, se tuvo en cuenta dos fases, la primera, la adecuación de la señal por medio de Hardware, dando como resultado una PCB (Circuito impreso, del inglés Pintad Circuito Borde ); en la segunda etapa se desarrolló un Software, que realiza el procesamiento dela señal, en este se implementa un índice de extubacion y se deja abierta la posibilidad de la implementación de nuevos índices en trabajos futuros. Este trabajo permite ver como una herramienta originada desde la ingeniería da la oportunidad de tomar una decisión rápida sin exponer al paciente a la hipoxemia.spa
dc.description.abstractPhysicians are currently facing one of the most complicated processes within this branch of science, because the recovery of patients is often measured by the respiratory capacity of each individual, becoming a high risk factor for patients. people who are in the intensive care units, reason for which this work proposes a prototype of Respiratory Flow Monitor, that allows the doctors to measure the respiratory capacity of each one of the patients, to be able to carry out the process of extubation with the lowest possible risk for their lives. With the advance in the research, the design of a prototype respiratory flow monitor for extubation index tests is proposed, which generates criteria for the evaluation of indexes, during the process, by the T-tube test method, helping the doctor in making decisions. For the elaboration of this prototype of Respiratory Flow Monitor for instantaneous breathing tests, two phases were taken into account, the first, the adaptation of the signal by means of Hardware, resulting in a PCB (Printed Circuit, of the English Pintad Circuito Edge); In the second stage, a software was developed, which performs signal processing, in which an index of extubation is implemented and the possibility of implementing new indexes in future work is left open. This work allows us to see how a tool originated from engineering gives the opportunity to make a quick decision without exposing the patient to hypoxemia.eng
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherEscuela Colombiana de Ingeniería Julio Garavitospa
dc.rightsDerechos Reservados - Escuela Colombiana de Ingeniería Julio Garavitospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/spa
dc.subjectMedicinaspa
dc.subjectTratamientos médicosspa
dc.subjectCircuitos Electrónicosspa
dc.titlePrototipo de monitor de flujo respiratorio para uso experimental en el estudio de índices de extubaciónspa
dc.typeTrabajo de grado - Maestríaspa
dc.type.versioninfo:eu-repo/semantics/publishedVersionspa
oaire.accessrightshttp://purl.org/coar/access_right/c_14cbspa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.description.degreelevelMaestríaspa
dc.description.degreenameMagíster en Ingeniería Electrónicaspa
dc.publisher.programMaestría en Ingeniería Electrónicaspa
dc.rights.accessrightsinfo:eu-repo/semantics/closedAccessspa
dc.rights.creativecommonsAtribución-NoComercial 4.0 Internacional (CC BY-NC 4.0)spa
dc.type.coarhttp://purl.org/coar/resource_type/c_bdccspa
dc.type.contentTextspa
dc.type.driverinfo:eu-repo/semantics/masterThesisspa
dc.type.redcolhttp://purl.org/redcol/resource_type/TMspa
dc.subject.keywordsMedicinespa
dc.subject.keywordsElectronics Circuitsspa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito
Excepto si se señala otra cosa, la licencia del ítem se describe como Derechos Reservados - Escuela Colombiana de Ingeniería Julio Garavito