Publication: Development df a Cost-Benefit and Risk Based Maintenance Model for Power Transformers
Files
Authors
Authors
Abstract (Spanish)
Abstract (English)
Director
Advisors/Directors
Extent
Collections
References
R. P. Hoskins, A. T. Brint, and G. Strbac, “A structured approach to Asset Manage- ment within the electricity industry”, Utilities Policy, vol. 7, no. 4, pp. 221–232, 1999, ISSN: 09571787. DOI: 10.1016/S0957-1787(98)00015-0
J. Schneider, A. J. Gaul, C. Neumann, J. Hografer, W. Wellßow, M. Schwan, and A. Schnettler, “Asset management techniques”, International Journal of Electrical Power and Energy Systems, vol. 28, no. 9 SPEC. ISS. Pp. 643–654, 2006, ISSN: 01420615. DOI: 10.1016/j.ijepes.2006.03.007.
L. S. Batista, H. E. Diniz, R. H. Takahashi, E. G. Carrano, F. Campelo, H. E. Di- niz, E. G. Carrano, F. Campelo, and L. S. Batista, “Multicriteria transformer asset management with maintenance and planning perspectives”, IET Generation, Trans- mission & Distribution, vol. 10, no. 9, pp. 2087–2097, 2016, ISSN: 1751-8687. DOI: 10 . 1049 / iet- gtd. 2015 . 1112. [Online]. Available: http:// digital- library. theiet.org/content/journals/10.1049/iet-gtd.2015.1112.
L. S. Rosero, Evaluación de esquemas de mantenimiento para transformadores de distribución, Universidad Nacional de Colombia Sede Bogotá, Bogotá, 2016.
I. C. Durán, “Metodología integral para gestión de activos en subestaciones de distribución”, Doctor en Filosofía de Ingeniería - Ingeniería Eléctrica. Línea de Investigación: Sistemas de Potencia y Calidad de la Energía, 2016, [Online]. Available: http: //bdigital.unal.edu.co/52466/.
R. Thurlby, “Managing the asset time bomb: a system dynamics approach”, Pro- ceedings of the Institution of Civil Engineers - Forensic Engineering, vol. 166, no. 3, pp. 134–142, 2013, ISSN: 2043-9903. DOI: 10.1680/feng.12.00026. [Online]. Available: http://www.icevirtuallibrary.com/doi/10.1680/feng.12.00026.
U. de Planeación Minero Energética-UPME, Plan de expansión referencia generación- transmisión 2016-2030, Ministerio de Minas y Energía, Colombia, 2016.
C. de Regulación de Energía y Gas, Resolución creg 011 de 2009, Ministerio de Minas y Energía, Colombia, 11 de Febrero de 2009.
C. de Regulación de Energía y Gas, Resolución creg 097 de 2008, Ministerio de Minas y Energía, Colombia, 28 de Septiembre de 2008.
C. de Regulación de Energía y Gas, Resolución creg 015 de 2018, Ministerio de Minas y Energía, Colombia, 29 de Enero de 2018.
“ISO 55000: Asset management - Overview, principles and terminology”, International Organization for Standardization, Switzerland, Standard, 2014.
A. N. Jahromi, R. Piercy, S. Cress, J. R. Service, and W. Fan, “An approach to power transformer asset management using health index”, IEEE Electrical Insulation Magazine, vol. 25, no. 2, pp. 20–34, 2009, ISSN: 08837554. DOI: 10.1109/MEI.2009. 4802595
R. E. Brown, G. Frimpong, and H. L. Willis, “Failure rate modeling using equipment inspection data”, IEEE Transactions on Power Systems, vol. 19, no. 2, pp. 782–787, 2004, ISSN: 08858950. DOI: 10.1109/TPWRS.2004.825824
Transformers Committee, IEEE Guide for Loading Mineral- Oil-Immersed Transformers and Step-Voltage Regulators IEEE Power & Energy Society, March. 2012, vol. 2011, ISBN: 9780738171951.
A. Azmi, J. Jasni, N. Azis, and M. Z. A. Kadir, “Evolution of transformer health index in the form of mathematical equation”, Renewable and Sustainable Energy Re- views, vol. 76, pp. 687–700, Sep. 2017, ISSN: 13640321. DOI: 10.1016/j.rser.2017. 03.094. [Online]. Available: https://linkinghub.elsevier.com/retrieve/pii/ S1364032117304306.
I. Durán, L. Rosero, A. Pavas, and O. Duarte, “Comparison of maintenance scheme effects on power transformer reliability performance”, Ingeniería e investigación, vol. 35, no. 1, pp. 73–81, 2015, ISSN: 2248-8723. DOI: 10.15446/ing.investig.v35n1Sup. 53435
Power IEEE Society Energy, IEEE Draft Guide for Acceptance and Maintenance of Insulating Mineral Oil in Electrical Equipment. 2015, vol. 2015, pp. 1–35, ISBN: VO -. DOI: 10.1534/genetics.104.032656
IEEE, Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers, 2009. DOI: 10.1109/IEEESTD.2009.4776518.
T. Committee, I. Power, and E. Society, IEEE Std C57.104-2008 (Revision of IEEE Std C57.104-1991), IEEE Guide for the Interpretation of Gases Generated in Oil- Immersed Transformers, February. 2009, vol. 2008, ISBN: 9780738158341. DOI: 10 . 1109/IEEESTD.2009.4776518.
M. Duval, “The duval triangle for load tap changers, non-mineral oils and low tem- perature faults in transformers”, Electrical Insulation Magazine, IEEE, vol. 24, pp. 22–29, Jan. 2009. DOI: 10.1109/MEI.2008.4665347
M. Duval and L. Lamarre, “The duval pentagon-a new complementary tool for the interpretation of dissolved gas analysis in transformers”, IEEE Electrical Insulation Magazine, vol. 30, no. 6, pp. 9–12, 2014, ISSN: 08837554. DOI: 10.1109/MEI.2014. 6943428
M. M. Mohsin, M. Rehman, R. S. Nema, and M. N. Narayanachar, “Measurement of transformer oil dielectric strength”, IEEE Region 10 Annual International Confer- ence, Proceedings/TENCON, vol. C, pp. 436–439, 2004. DOI: 10.1109/tencon.2004. 1414801.
S. Kumpalavalee, T. Suwanasri, C. Suwanasri, S. Wattanawongpitak, T. Sooksodkiao, P. Tanprasert, and B. Kaewkamthong, “Condition evaluation of power transformers using dissolved gas analysis and dielectric breakdown voltage test”, 2017 International Electrical Engineering Congress, iEECON 2017, 2017. DOI: 10.1109/IEECON.2017. 8075803.
S. Forouhari and A. Abu-Siada, “Remnant life estimation of power transformer based on IFT and acidity number of transformer oil”, Proceedings of the IEEE International Conference on Properties and Applications of Dielectric Materials, vol. 2015-Octob, pp. 552–555, 2015. DOI: 10.1109/ICPADM.2015.7295331.
S. Forouhari, A. Abu-Siada, N. Lelekakis, J. Wijaya, D. Martin, and D. Susa, “The effect of acid accumulation in power-transformer oil on the aging rate of paper insu- lation”, IEEE Electrical Insulation Magazine, vol. 30, no. 3, pp. 19–26, 2014, ISSN: 08837554. DOI: 10.1109/MEI.2014.6804738
H. Ding, R. Heywood, P. Griffin, and L. Lewand, “An overview of water and relative saturation in power transformers”, 2017 IEEE 19th International Conference on Di- electric Liquids, ICDL 2017, vol. 2017-Janua, no. Icdl, pp. 1–4, 2017. DOI: 10.1109/ ICDL.2017.8124640.
W. D. Hillary, K. L. Jayarathna, L. I. Ranasinghe, S. M. Samarakoon, N. M. Rath- nayake, J. R. Lucas, and R. Samarasinghe, “A tool for estimating remaining life time of a power transformer”, 3rd International Moratuwa Engineering Research Conference, MERCon 2017, pp. 373–378, 2017. DOI: 10.1109/MERCon.2017.7980513.
K. B. Shaban, A. H. El-Hag, and K. Benhmed, “Prediction of Transformer Furan Levels”, IEEE Transactions on Power Delivery, vol. 31, no. 4, pp. 1778–1779, 2016, ISSN: 08858977. DOI: 10.1109/TPWRD.2016.2521320.
C. Lin, B. Zhang, and Y. Yuan, “The aging diagnosis of solid insulation for oil-immersed power transformers and its remaining life prediction”, in 2010 Asia-Pacific Power and Energy Engineering Conference, 2010, pp. 1–3. DOI: 10.1109/APPEEC.2010.5449486.
IEEE Standards Association, IEEE Guide for Loading Mineral- Oil-Immersed Trans- formers and Step-Voltage Regulators, 2012. DOI: 10.1109/IEEESTD.2012.6166928. [Online]. Available: http : / / ieeexplore . ieee . org / stamp / stamp . jsp ? tp = &arnumber=6166928.
T. W. Dakin, Electrical Insulation Deterioration Treated as a Chemical Rate Phenomenon, 1. 1948, vol. 67, pp. 113–122. DOI: 10.1109/T-AIEE.1948.5059649.
Y. Li, M. J. Tang, F. J. Wu, G. J. Zhang, S. H. Wang, and Suwarno, “Aging assessment of power transformer using multi-parameters”, International Journal on Electrical Engineering and Informatics, vol. 5, no. 1, pp. 34–44, 2013, ISSN: 20875886. DOI: 10.15676/ijeei.2013.5.1.4
IEEE Standards Association, IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors. 2013, vol. 2013, pp. 1–121, ISBN: 9780738183695. DOI: 10.1109/IEEESTD.2013.6544533.
D. F. G. Gómez, “Determinación de coeficientes de difusión de humedad en papeles aislantes de transformador”, Doctor en Ingeniería Eléctrica, Electrónica y Automática, 2012, [Online]. Available: http://hdl.handle.net/10016/15020
L. S. Rosero, D. L. Alvarez, F. J. Amortegui, G. Hernández, and S. R. García, “A framework for asset management in electrical systems, part ii: Case study - power transformers”, in 2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA), 2019, pp. 1–6. DOI: 10.1109/PEPQA.2019.8851551.
R. E. Brown, Electric power distribution reliability. Boca Raton: CRC Press, 2008. DOI: https://doi.org/10.1201/9780849375682.
T. Short, Electric Power Distribution Handbook, Second Edition. 2014, ISBN: 978-1- 4665-9865-2. DOI: 10.1201/b16747. [Online]. Available: http://www.crcnetbase. com/doi/book/10.1201/b16747.
K. Baburao, N. M. Bhangre, A. M. Wagle, A. Venkatasami, and S. E. Chaudhari, “The experience of DP and furan in remnant life assessment of power transformer”, Proceedings of 2008 International Conference on Condition Monitoring and Diagnosis, CMD 2008, no. October 2015, pp. 555–558, 2008. DOI: 10.1109/CMD.2008.4580348.
J. Wang, J. Lu, Z. Bie, S. You, and X. Cao, “Long-term maintenance scheduling of smart distribution system through a PSO-TS algorithm”, Journal of Applied Mathe- matics, vol. 2014, 2014, ISSN: 16870042. DOI: 10.1155/2014/694086.
I. C. Durán and O. G. Duarte, “A survey of methods of estimating lifetime and aging of assets in substations”, 9th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2012), no. 978-1-84919-743-4, pp. 1–6, 2012. DOI: 10.1049/cp.2012.2141.
“PAS 55 : 2008 - Management System Structure”, British Standards Institution, Lon- don, United Kingdom, Standard, 2008.
“ISO 55001: Asset management - Management systems - Requirements”, International Organization for Standardization, Switzerland, Standard, 2014.
“ISO 55002: Asset management - Management systems - Guidelines for the application of ISO 55001”, International Organization for Standardization, Switzerland, Standard, 2014.
D. L. Alvarez, L. S. Rosero, S. R. Rivera, and A. A. Romero, “A framework for asset management in electrical systems, part i: Conceptual model”, in 2019 IEEE Workshop on Powerc Electronics and Power Quality Applications (PEPQA), 2019, pp. 1–6. DOI: 10.1109/PEPQA.2019.8851575.
A. Abu-Siada, S. Hmood, and S. Islam, “A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis”, IEEE Transactions on Dielectrics and Electrical Insulation, vol. 20, no. 6, pp. 2343–2349, 2013, ISSN: 10709878. DOI: 10 . 1109/TDEI.2013.6678888.
W. Fu, J. D. McCalley, and V. Vittal, “Risk assessment for transformer loading”, IEEE Transactions on Power Systems, vol. 16, no. 3, pp. 346–353, 2001, ISSN: 08858950. DOI: 10.1109/59.932267.
A. E. Abu-Elanien, M. M. Salama, and M. Ibrahim, “Calculation of a health index for oil-immersed transformers rated under 69 kV using fuzzy logic”, IEEE Transactions on Power Delivery, vol. 27, no. 4, pp. 2029–2036, 2012, ISSN: 08858977. DOI: 10.1109/ TPWRD.2012.2205165.
M. Arshad and S. M. Islam, “A novel fuzzy logic technique for power transformer asset management”, Conference Record - IAS Annual Meeting (IEEE Industry Applications Society), vol. 1, no. c, pp. 276–286, 2006, ISSN: 01972618. DOI: 10.1109/IAS.2006. 256536.
L. Rosero-Z, A. Pavas, and I. C. Durán, “Analysis of maintenance in transformers based on a fuzzy logic method”, in 2018 IEEE PES Transmission Distribution Conference and Exhibition - Latin America (T&D-LA), 2018, pp. 1–5. DOI: 10.1109/TDC- LA. 2018.8511772.