Connection between a Column and its Foundation for Guadua Angustifolia Structures under Lateral Loads
(Trans Tech Publications INC. Materials Science & Engineering, 2015)
In Colombia, as in other developing regions, social housing shortage related problems has led local authorities to propose low cost housing projects that allow its quickly and easy construction. Among the requirements of ...
Evaluation of the Permeation Properties of Concrete Added with a Petrochemical Industry Waste
(Springer Nature, 2015)
In this work, the evaluation of the performance of concrete added with a petrochemical industry waste called Fluid Catalytic Cracking Catalyst residue (FCC) from a Colombian petroleum company is presented. Results of this ...
Resistance of blended concrete containing an industrial petrochemical residue to chloride ion penetration and carbonation
(Universidad Nacional de Colombia, 2014)
In this study, the resistance of blended concrete containing catalytic cracking residue (FCC) to chloride ion penetration and carbonation was examined. FCC was added at the levels of 10%, 20%, and 30% as partial replacement ...
Desempeño mecánico y durable de concretos que incorporan agregado reciclado fino comercial
(Universidad EIA, 2019)
En este artículo se presentan los resultados de un estudio de viabilidad técnica de uso de agregado reciclado fino comercial (ARF) proveniente de concretos de las actividades de construcción y demolición (RC&D), en la ...
Rigidez de una conexión de columna-cimentación para estructuras de Guadua angustifolia Kunth
(Universidad de la Salle, 2014)
Una de las limitantes que encuentran los ingenieros estructurales para el diseño de una edificación y, en general, de cualquier estructura en Guadua angustifolia Kunth es la falta de información técnica relacionada con ...
Performance under sulfate attack of concrete additioned with fluid catalytic cracking catalyst residue (FCC) and metakaolin (MK)
(Universidad Nacional de Colombia, 2013)
In this work the evaluation of the performance of concrete added with Fluid Catalytic Cracking Catalyst residue (FCC) from a Colombian petroleum company, under sulfate attack, is presented. The results of this concrete are ...
Using spent fluid catalytic cracking (FCC) catalyst as pozzolanic addition - a review
(Universidad Nacional de Colombia, 2010)
El catalizador gastado de craqueo catalítico (FCC) es un residuo procedente de las unidades de ruptura catalítica en lecho fluido de la industria del petróleo. Este residuo está conformado principalmente por un componente ...
Evaluation of internal curing effects on concrete
(Universidad Nacional de Colombia, 2019)
The objective of the present research was the evaluation of some fresh and hardened-state properties of concretes, in which coarse aggregates were partially replaced by lightweight ones previously saturated, in percentages ...
Evaluación de la resistencia a compresión en morteros de cal, sometidos a diferentes condiciones de curado
(Escuela Colombiana de Ingeniería Julio Garavito, 2019)
En este artículo se presenta la evaluación de la resistencia a compresión en morteros de cal, sometidos a diferentes condiciones de curado y diferentes edades de ensayo. En total, se evaluaron las propiedades ...
Assessment of Anchorage Methods and FRP Laminate Strengthening Configurations for URM Walls Under In-Plane Loading
(American Concrete Institute, 2018)
In order to ensure a continuous and reliable path for the lateral loads caused by earthquake or wind forces, FRP-strengthened masonry walls that are part of the lateral load resisting system of a building require the joint ...