Publication: Shear behavior of post-installed anchor connections strengthened with CFRP laminates
Loading...
Files
Authors
Authors
Abstract (Spanish)
El arrancamiento del concreto es un modo de falla que limita la máxima capacidad alcanzable de sistemas de anclaje solicitados a cortante ubicados cerca a un borde libre. El refuerzo preinstalado ha demostrado mejorar el comportamiento de este tipo de anclajes. Sin embargo, esta alternativa es más efectiva si el sistema de anclaje también es preinstalado. Por ende, se llevó a cabo un programa experimental para evaluar la respuesta a cortante de anclajes adhesivos individuales reforzados con láminas de CFRP posinstaladas, y se contrastaron sus resultados con aquellos de especímenes no reforzados, así como también de anclajes reforzados con una alternativa fundida in situ (gancho de acero). Se evaluaron cuatro configuraciones de reforzamiento con CFRP para cada distancia al borde considerada (50 mm, 100 mm). Además, se elaboraron modelos puntal-tensor para el diseño de cada alternativa de reforzamiento, variando también el área de refuerzo del CFRP. Se analizó carga máxima, absorción de energía, deformaciones unitarias y modo de falla. Los resultados demostraron que los especímenes reforzados con CFRP lograron cargas máximas que variaban entre 2.7 y 5.4, y entre 1.8 y 2.1 veces aquellas correspondientes a especímenes no reforzados ubicados a 50 mm y 100 mm del borde, respectivamente. Además, el modo de falla de varios especímenes cambió a uno dado por ruptura del anclaje, que es el estado límite asociado con la máxima capacidad a cortante.
Abstract (English)
Concrete breakout is a common failure mode that limits the maximum achievable capacity of shear-loaded anchoring systems installed close to a free edge. Cast-in anchor reinforcement has proved to improve the behavior of this type of anchors. However, this alternative is most effective if the fastening system is also cast-in place. As a result, an experimental program was carried out to assess the shear response of bonded single anchors strengthened with post-installed CFRP laminates and compare their results with those of unreinforced specimens and anchors strengthened with a cast-in alternative (steel hairpin). Four CFRP reinforcement configurations were evaluated for each edge distance considered (50 mm, 100 mm). Strut-and-tie models were elaborated for the design of each reinforcement alternative, while also varying the area of CFRP reinforcement. Ultimate load, absorbed energy, strain unit behavior and failure mode were analyzed. The results showed that CFRP-reinforced specimens achieved ultimate loads that ranged from 2.7 to 5.4 and from 1.8 to 2.1 times that of unreinforced 50 mm and 100 mm specimens, respectively. Also, the failure mode in various specimens changed to anchor rupture, which is the limit state associated with the maximum shear capacity.
Director
Advisors/Directors
Extent
190 páginas
Collections
How to cite
APA
Tami Torres, Kevin Andrés (2024). Shear behavior of post-installed anchor connections strengthened with CFRP laminates.
MLA
Tami Torres, Kevin Andrés. "Shear behavior of post-installed anchor connections strengthened with CFRP laminates." 2024.
Chicago
Tami Torres, Kevin Andrés. 2024. "Shear behavior of post-installed anchor connections strengthened with CFRP laminates."